Please Note: We are Closed until Further Notice due to Coronavirus Pandemic.
{"id":4514818687115,"title":"Din Rail Modular Contactor 230V AC 25A","handle":"din-rail-modular-contactor-230v-ac-25a","description":"TOCT1 2P 25A 220V\/230V 50\/60HZ Din rail AC Modular contactor with 1NO 1NC\u003cbr\u003e\u003cbr\u003eTOCT1 house hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V . Rated operating voltage in AC-7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC-7b usage , rated current to 10A.  Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.\u003cbr\u003e\u003cbr\u003eApplication: for home, apartment, hotel, automatic cut off or connect the power.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNormal working and installation conditions:\u003c\/strong\u003e\u003cbr\u003e1. Ambient temperature:-5°C to +40°C,the average temperature no more than +35°C in 24 hours.\u003cbr\u003e2. Altitude:no more than 2000m.\u003cbr\u003e3. Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40°C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25°C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.\u003cbr\u003e4. Class of pollution: class 2.\u003cbr\u003e5. Installation condition: class II.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication instruction:\u003c\/strong\u003e\u003cbr\u003e1. Check whether the contactor agrees with the scope of application and the working condition before installation\u003cbr\u003e2. During the process of installing pull down the motion stopping component and put the contactor on the safe orbit then push up the motion-stopping component to fix the contactor on the safe orbit avoid loosening and dropping pull down the motion-stopping component if you want to remove the contactor.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCaution\u003c\/strong\u003e\u003c\/span\u003e:\u003cbr\u003ea).Make sure the correct mode of connection\u003cbr\u003eb).Screw down the binding screw during the connection \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTECHNICAL DETAILS:\u003cbr\u003eBrand: TOMZN\u003cbr\u003eModel: TOCT1-25\u003cbr\u003e\u003c\/strong\u003eRated isolating voltage (Ui) V:     500\u003cbr\u003eRated operating voltage (Ue) V:     230\u003cbr\u003eThermal continuous current (Ith) A:     25\u003cbr\u003eRated working current (Ie) AC-7a A:    25\u003cbr\u003eAC-7b A:     10\u003cbr\u003eRated working power (Pe) AC-7a kW:     5.4\u003cbr\u003eAC-7b A kW:     1.4\u003cbr\u003eOperating times 10 thousand     aeProduct.getSubject(): 3\u003cbr\u003eOperating frequency AC-7a turns\/Hour:     1200\u003cbr\u003eAC-7b turns\/Hour:     30\u003cbr\u003eConnect and break capability AC-7a A:     1.5Ie\u003cbr\u003eAC-7b A:     8Ie\u003cbr\u003eWithstand current (ICW) 10S A:     8Ie\/AC-7b\u003cbr\u003eConnecting wiring  1 wire mm2:    1--4\u003cbr\u003e 2 wire mm2:      1--4\u003cbr\u003e\u003cstrong\u003eCoil:\u003c\/strong\u003e\u003cbr\u003eControl power voltage (Us) AC V:     220\/230\u003cbr\u003eCoil power W :    1.4\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1Pc TOCT1 2P 25A 220V\/230V 50\/60HZ Din rail AC Modular contactor 1NO 1NC\u003cbr\u003e\u003c\/p\u003e","published_at":"2020-02-05T13:59:24+05:30","created_at":"2020-02-05T13:59:24+05:30","vendor":"TOMZN","type":"Switches \u0026 Outlets","tags":["AC Contactor","Contactor","Relay"],"price":145000,"price_min":145000,"price_max":145000,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":32159760318603,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"Din Rail Modular Contactor 230V AC 25A","public_title":null,"options":["Default Title"],"price":145000,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/TOCT1-2P-25A.jpg?v=1580892037","\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/ac_contactor.jpg?v=1580892046"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/TOCT1-2P-25A.jpg?v=1580892037","options":["Title"],"media":[{"alt":null,"id":6323519783051,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/TOCT1-2P-25A.jpg?v=1580892037"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/TOCT1-2P-25A.jpg?v=1580892037","width":500},{"alt":null,"id":6323520798859,"position":2,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/ac_contactor.jpg?v=1580892046"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1486\/8295\/products\/ac_contactor.jpg?v=1580892046","width":500}],"content":"TOCT1 2P 25A 220V\/230V 50\/60HZ Din rail AC Modular contactor with 1NO 1NC\u003cbr\u003e\u003cbr\u003eTOCT1 house hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V . Rated operating voltage in AC-7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC-7b usage , rated current to 10A.  Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.\u003cbr\u003e\u003cbr\u003eApplication: for home, apartment, hotel, automatic cut off or connect the power.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNormal working and installation conditions:\u003c\/strong\u003e\u003cbr\u003e1. Ambient temperature:-5°C to +40°C,the average temperature no more than +35°C in 24 hours.\u003cbr\u003e2. Altitude:no more than 2000m.\u003cbr\u003e3. Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40°C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25°C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.\u003cbr\u003e4. Class of pollution: class 2.\u003cbr\u003e5. Installation condition: class II.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication instruction:\u003c\/strong\u003e\u003cbr\u003e1. Check whether the contactor agrees with the scope of application and the working condition before installation\u003cbr\u003e2. During the process of installing pull down the motion stopping component and put the contactor on the safe orbit then push up the motion-stopping component to fix the contactor on the safe orbit avoid loosening and dropping pull down the motion-stopping component if you want to remove the contactor.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCaution\u003c\/strong\u003e\u003c\/span\u003e:\u003cbr\u003ea).Make sure the correct mode of connection\u003cbr\u003eb).Screw down the binding screw during the connection \u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTECHNICAL DETAILS:\u003cbr\u003eBrand: TOMZN\u003cbr\u003eModel: TOCT1-25\u003cbr\u003e\u003c\/strong\u003eRated isolating voltage (Ui) V:     500\u003cbr\u003eRated operating voltage (Ue) V:     230\u003cbr\u003eThermal continuous current (Ith) A:     25\u003cbr\u003eRated working current (Ie) AC-7a A:    25\u003cbr\u003eAC-7b A:     10\u003cbr\u003eRated working power (Pe) AC-7a kW:     5.4\u003cbr\u003eAC-7b A kW:     1.4\u003cbr\u003eOperating times 10 thousand     aeProduct.getSubject(): 3\u003cbr\u003eOperating frequency AC-7a turns\/Hour:     1200\u003cbr\u003eAC-7b turns\/Hour:     30\u003cbr\u003eConnect and break capability AC-7a A:     1.5Ie\u003cbr\u003eAC-7b A:     8Ie\u003cbr\u003eWithstand current (ICW) 10S A:     8Ie\/AC-7b\u003cbr\u003eConnecting wiring  1 wire mm2:    1--4\u003cbr\u003e 2 wire mm2:      1--4\u003cbr\u003e\u003cstrong\u003eCoil:\u003c\/strong\u003e\u003cbr\u003eControl power voltage (Us) AC V:     220\/230\u003cbr\u003eCoil power W :    1.4\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1Pc TOCT1 2P 25A 220V\/230V 50\/60HZ Din rail AC Modular contactor 1NO 1NC\u003cbr\u003e\u003c\/p\u003e"}

Din Rail Modular Contactor 230V AC 25A

Product Description
Rs 1,450.00
Maximum quantity available reached.
TOCT1 2P 25A 220V/230V 50/60HZ Din rail AC Modular contactor with 1NO 1NC

TOCT1 house hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V . Rated operating voltage in AC-7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC-7b usage , rated current to 10A.  Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.

Application: for home, apartment, hotel, automatic cut off or connect the power.

Normal working and installation conditions:
1. Ambient temperature:-5°C to +40°C,the average temperature no more than +35°C in 24 hours.
2. Altitude:no more than 2000m.
3. Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40°C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25°C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.
4. Class of pollution: class 2.
5. Installation condition: class II.

Application instruction:
1. Check whether the contactor agrees with the scope of application and the working condition before installation
2. During the process of installing pull down the motion stopping component and put the contactor on the safe orbit then push up the motion-stopping component to fix the contactor on the safe orbit avoid loosening and dropping pull down the motion-stopping component if you want to remove the contactor.

Caution:
a).Make sure the correct mode of connection
b).Screw down the binding screw during the connection

 

TECHNICAL DETAILS:
Brand: TOMZN
Model: TOCT1-25
Rated isolating voltage (Ui) V:     500
Rated operating voltage (Ue) V:     230
Thermal continuous current (Ith) A:     25
Rated working current (Ie) AC-7a A:    25
AC-7b A:     10
Rated working power (Pe) AC-7a kW:     5.4
AC-7b A kW:     1.4
Operating times 10 thousand     aeProduct.getSubject(): 3
Operating frequency AC-7a turns/Hour:     1200
AC-7b turns/Hour:     30
Connect and break capability AC-7a A:     1.5Ie
AC-7b A:     8Ie
Withstand current (ICW) 10S A:     8Ie/AC-7b
Connecting wiring  1 wire mm2:    1--4
 2 wire mm2:      1--4
Coil:
Control power voltage (Us) AC V:     220/230
Coil power W :    1.4

Package Includes:

1Pc TOCT1 2P 25A 220V/230V 50/60HZ Din rail AC Modular contactor 1NO 1NC

Product Code:
Brand: TOMZN